Duracell POWERPACK 600 Spezifikationen Seite 45

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 58
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 44
Troubleshooting Reference
975-0213-01-01 35
Over-
temperature
shutdown
Inverter has
overheated due to poor
ventilation or
excessively warm
environmental
conditions.
Turn off the AC outlet
ON/OFF
switch, and let the XPower
Powerpack cool down.
Alarm sounds Internal battery is
nearly discharged.
(11.0 V).
If you ignore this
warning, the XPower
Powerpack
automatically switches
off when the battery
reaches 10.5 V.
Turn the AC outlet
ON/OFF switch
OFF and recharge the XPower
Powerpack.
Run time is
less than
expected.
Internal battery is not
fully charged.
AC appliance power
consumption is higher
than expected.
Recharge using the AC charger, until
green Charging Status light is
steady.
Check AC appliance power or
wattage rating (or current draw for
12 V DC appliances) and compare
with Table 3-1 on page 15 and Table
3-2 on page 18.
Table 5-1
Troubleshooting reference
Problem Possible Cause Solution
Seitenansicht 44