Duracell Powerpack 300 Spezifikationen Seite 40

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 47
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 39
30
Troubleshooting Reference
WARNING: Electric shock hazard
Do not remove the cover of the Duracell
®
Powerpack or
disassemble the Duracell
®
Powerpack except to replace
the internal battery or 250 A fuse. The Duracell
®
Powerpack
does not contain any internal user-serviceable parts and
attempting to service the unit yourself could result in
electrical shock or burn.
Table 5-1 Troubleshooting reference
Problem Possible Cause Solution
AC appliance will not
operate;
Audible alarm is not
sounding.
AC appliance rated more
than 480 W, the safety
overload has tripped. AC
appliance is rated less
than 480 W, high starting
surge has tripped the
safety overload
Use an AC appliance with a
power rating less than 480 W.
AC appliance may exceed the
unit’s surge capability. Use an
AC appliance with a starting
surge within the Duracell
®
Powerpack surge rating.
Overload shutdown Appliance power
requirements exceed the
capability of the Duracell
®
Powerpack.
Unplug the appliance and
con rm that the appliance’s
power requirement is 480 W
or less before attempting to
restart the appliance.
AC appliance will not
operate; audible alarm is
sounding.
Battery has discharged
to 10.5 V. Inverter has
overheated due to poor
ventilation or excessively
warm environmental
conditions.
Turn the AC outlet ON/OFF
switch off and recharge the
Duracell
®
Powerpack. Turn
the AC outlet ON/OFF switch
off and allow the Duracell
®
Powerpack to cool for 15
minutes or more. Clear blocked
fan opening or remove objects
covering the unit, then restart
the Duracell® Powerpack.
Move to a cooler environment.
Over-temperature
shutdown
Inverter has overheated
due to poor ventilation
or excessively warm
environmental conditions.
Turn off the AC outlet ON/OFF
switch, and let the Duracell
®
Powerpack cool down.
Alarm sounds Internal battery is nearly
discharged.(11.0 V). If
you ignore this warning,
the Duracell
®
Powerpack
automatically switches off
when the battery reaches
10.5 V.
Turn the AC outlet ON/OFF
switch OFF and recharge the
Duracell
®
Powerpack.
Seitenansicht 39
1 2 ... 35 36 37 38 39 40 41 42 43 44 45 46 47

Kommentare zu diesen Handbüchern